Processus d’installation

L’installation du système antigivre de Borealis minimise les temps d’arrêt et les coûts communément associés aux solutions de modernisation. Pas besoin d’utiliser de grues, ni de cordes, pas de perte de production, même de nuit.

IR_1606.jpg

Case Studies

Case Study 1: Predicted vs. Measured Conditions and Results

This image shows a heated 50-meter long blade. This is an infrared photo taken from the ground of an 80-meter tower. The heating is targeted to the leading edge of the blade, which you can see from the spot temperatures. The leading edge shows a temperature between 15.7°C and 21.2°C depending on the location. Due to the distance that the infrared photo was taken from, there may be +/-2°C of error.

This table shows the predicted temperatures and the measured temperatures. The ambient conditions where -2°C degrees Celsius with wind speed around 2.2m/s. The predicted blade surface temperature was between 14.5°C to 20.0°C.

Turbine: Idle Predicted Measured
Ambient Temperature (°C) -2 -2
Wind Speed (m/s) 2.2 1.2 to 3.2
Blade Surface Temperature (°C) 14.5 to 20.0 15.7 to 21.2 (+/-2)

Case Study 2: Predicted vs. Measured Conditions and Results

This image shows a heated 50-meter long blade. This is an infrared photo taken from the ground of an 80-meter tower. The heating is targeted to the leading edge of the blade, which you can see from the spot temperatures. The leading edge shows a temperature between 8.3°C and 13.6°C depending on the location. Due to the distance that the infrared photo was taken from, there may be +/-2°C of error.

This table shows the predicted temperatures and the measured temperatures. The ambient conditions where -7°C degrees Celsius with wind speed around 5.8 m/s. The predicted blade surface temperature was between 6.3°C to 12.9°C.

IR_2034.jpg
Turbine: Idle Predicted Measured
Ambient Temperature (°C) -7 -7
Wind Speed (m/s) 5.8
4.8 to 6.8
Blade Surface Temperature (°C) 6.3 to 12.9 8.3 to 13.6 (+/-2)

System Performance

Blade De-icing Photos.jpg

The above photos show before, left, and after, right, of a wind turbine that was using the Borealis de-icing system. In under 30 minutes the ice buildup was shed, and the turbine was able to resume operation. A de-icing time of under 30 minutes would be expected in most conditions.

Installation électrique

Le système antigivre Borealis se compose du système de réchauffement de la lame et de plusieurs centre de contrôle : dans chaque pale, dans le moyeu ainsi que dans la nacelle. Ce système de contrôle est intégrant à la chaîne de sûreté et rassemble les données du système SCADA. Une remise à niveau du circuit d’alimentation et/ou de l’anneau coulissant peuvent être nécessaire dépendant du modèle de la turbine.

bladeCabinet (1) (1).jpg

Prévention des risques

Un réseau de capteurs installés le long de la pale et dans la turbine surveille activement l’état du système et prévient d’éventuels états défectueux. Afin de nous assurer que Borealis offre les plus hauts niveaux de sécurité, de fiabilité et de confiance pour le propriétaire comme pour l’exploitant, nous sommes en constant développement de notre technologie en collaboration avec des centres d’essai universitaires, des organismes de recherche indépendants et des partenaires industriels

turbine-graphic.png

Become An Early Adopter 

Réduit les temps d’arrêts

protège votre investissement

service prioritaire